Megazyme柠檬酸检测试剂盒

Megazyme柠檬酸检测试剂盒
上海金畔生物科技有限公司
品牌:Megazyme

英文名:Citric Acid Assay Kit

货号:K-CITR

规格:72 assays (manual) / 720 assays

分析物意义: 常见食品组分和添加剂 

Megazyme检测试剂盒优点:适用于手工和自动分析仪进行检测。重组的柠檬酸裂解酶-20摄氏度的稳定性>6个月。试剂稳定 

A flexible and simple method for the rapid and reliable measurement of citric acid (citrate) in foods, beverages and other materials. Content: 72 assays per kit

UV-method for the determination of Citric Acid in foods,
beverages and other materials

Principle:
(citrate lyase)
(1) Citrate → oxaloacetate + acetate

(L-malate dehydrogenase)
(2) Oxaloacetate + NADH + H+ → L-malate + NAD+

(D-lactate dehydrogenase)
(3) Pyruvate + NADH + H+ → D-lactate + NAD+

Kit size: 72 assays (manual) / 720 (microplate)
/ 840 (auto-analyser)
Method: Spectrophotometric at 340 nm
Reaction time: ~ 5 min
Detection limit: 0.921 mg/L
Application examples:
Grape juice, wine, beer, fruit juices, soft drinks, tea, dairy products
(e.g. cheese), meat, processed meat, vegetable and fruit products,
bakery products, paper, pharmaceuticals, cosmetics and other
materials (e.g. biological cultures, samples, etc.)
Method recognition:
Methods based on this principle have been accepted by MEBAK, OIV,
EU, ISO2963, AOAC and IFU22
(Note: If the enzyme oxaloacetate decarboxylase is present in the sample, some
of the oxaloacetate product is converted to pyruvate. Therefore, to ensure citric
acid is measured quantitatively, D-lactate dehydrogenase (D-LDH) is employed
to efficiently convert any pyruvate produced into D-lactate and NAD+).

Advantages

  • Reconstituted citrate lyase stable for 4 weeks at 4°C / 6 months at -20°C
  • Buffer / cofactor / enzyme tablets for efficient use of kit components
  • PVP incorporated to prevent tannin inhibition
  • Very competitive price (cost per test)
  • Mega-Calc™software tool is available from our website for hassle-free raw data processing
  • Standard included
  • Extended cofactors stability
  • Suitable for manual, microplate and auto-analyser formats

Q1. Sometimes a negative absorbance change is obtained for the blank samples, is this normal? Should the real value (negative absorbance change) or “0” be used in the calculation of results?

Sometimes the addition of the last assay component can cause a small negative absorbance change in the blank samples due to a dilution effect and in such cases it is recommended that the real absorbance values be used in the calculation of results.

Q2. Should the pH of the sample be adjusted even for samples in acidic media?

The pH of the assay solution after the sample is added should be the same as that of the assay buffer that is supplied with the kit.
Low sample volumes (e.g. 0.1 mL) are not likely to affect the pH of the assay solution and therefore may not require pH adjustment.
Samples above 0.1 mL are more likely to affect the pH of the assay solution and therefore the pH of these samples should be adjusted as described in the data booklet, prior to addition to the assay.

Q3. Is the Citric Acid test kit (K-CITR) suitable for measurement using cell culture media samples?

Yes, assuming that the concentration of the analyte in the sample (after sample preparation) is above the limit of detection for the kit.  It may be sufficient to use the sample directly in the assay after clarification by centrifugation / filtering followed but dilution (if required) in distilled water. 

Q4. There is an issue with the performance of the kit; the results are not as expected.

If you suspect that the Megazyme test kit is not performing as expected such that expected results are not obtained please do the following:

  1. Ensure that you have tested the standard sample that is supplied with the Megazyme test kit.
  2. Send the results of the kit standard, blank samples and the results obtained for your sample,  in the relevant MegaCalc spreadsheet (if available) to Megazyme (cs@megazyme.com). Where available the relevant MegaCalc spreadsheet can be downloaded from where the product appears on the Megazyme website.
  3. State the kit lot number being used (this is found on the outside of the kit box).
  4. State which assay format was used (refer to the relevant page in the kit booklet if necessary).
  5. State exact details of any modifications to the standard procedure that is provided by Megazyme.
  6. State the sample type and describe the sample preparation steps if applicable.

Q5. The pH of my sample is low (pH ~ 3.0), do I need to adjust this before I use the sample in the kit assay?

The final pH of the kit assay after the sample is added should not change from what it should be (as stated in the kit for the assay buffer). If it does change then the sample will require pH adjustment. In most cases the sample volume being used is low relative to the final assay volume and in this case the pH of the kit assay is unlikely to be affected.

Q6. How can I work out how much sample to extract and what dilution of my sample should be used in the kit assay?

Where the amount of analyte in a liquid sample is unknown, it is recommended that a range of sample dilutions are prepared with the aim of obtaining an absorbance change in the assay that is within the linear range.
Where solid samples are analysed, the weight of sample per volume of water used for sample extraction/preparation can be altered to suit, as can the dilution of the extracted sample prior to the addition of the assay, as per liquid samples.

Q7. Can you explain, step by step, how to follow the method and perform the kit assay?

For users who are not familiar with how to use the Megazyme tests kits then it is recommended that they follow this example, e.g. D-Fructose/D-Glucose Assay kit K-FRUGL (http://secure.megazyme.com/D-Fructose-D-Glucose-Assay-Kit):

1. The kit components are listed on pages 2-3 of the kit booklet.
2. Prepare the kit reagents as described on page 3.
3. For separate measurements of glucose and fructose follow procedure A on page 4.
4. Pipette the volumes listed for water, sample, solution 1 and solution 2 into 3 mL, 1 cm pathlength cuvettes. Duplicate sample assays and duplicate blanks are recommended. Mix the contents of each cuvette by inversion (seal the cuvette using parafilm or a plastic cuvette cap – do not use a finger) then after ~3 min record the first absorbance reading of each cuvette at 340 nm (this is reading A1).
5. Then add suspension 3 and mix the contents of each cuvette by inversion. Incubate for 5 minutes then record the absorbance reading of each cuvette at 340 nm (this is reading A2). NB. It is essential that the reaction is compete. To assess this, record the absorbances at ~ 2 minute intervals and until the absorbance plateaus. A stable absorbance indicates that the reaction is complete. If the absorbance continues to increase then continue to record absorbances until it plateaus and only then record absorbance reading A2.
6. Then add suspension 4 and mix the contents of each cuvette by inversion. Incubate for 5 minutes then take absorbance reading of each cuvette at 340 nm (this is reading A3). NB. As above, assess that the reaction has completed by take subsequent readings at ~2 min intervals.
7. For simple, automated results analysis, input the absorbance readings (A1, A2, A3) for samples and blanks into the K-FRUGL MegaCalc.

To ensure that the assay is working, and being performed correctly it is recommend that the test is performed using the standard sample that is provided with the kit and to obtain the expected values before proceeding to test real samples.
It is recommend that new users also watch this video which highlights how to perform the assays.
Many of the other Megazyme test kits follow a similar format.

Q8. I have some doubts about the appearance/quality of a kit component what should be done?

If there are any concerns with any kit components, the first thing to do is to test the standard sample (control sample) that is supplied with the kit and ensure that the expected value (within the accepted variation) is obtained before testing any precious samples. This must be done using the procedure provided in the kit booklet without any modifications to the procedure. If there are still doubts about the results using the standard sample in the kit then send example results in the MegaCalc spread sheet to your product supplier (Megazyme or your local Megazyme distributor).

Q9. Can the sensitivity of the kit assay be increased?

For samples with low concentrations of analyte the sample volume used in the kit assay can be increased to increase sensitivity. When doing this the water volume is adjusted to retain the same final assay volume. This is critical for the manual assay format because the assay volume and sample volume are used in the calculation of results.

Q10. How much sample should be used for the clarification/extraction of my sample?

The volume/weight of sample and total volume of the extract can be modified to suit the sample. This will ultimately be dictated by the amount of analyte of interest in the sample and may require empirical determination. For low levels of analyte the sample:extract volume ratio can be increased (i.e. increase the sample and/or decrease the total extraction volume).

Alternatively, for samples with low concentrations of analyte, a larger sample volume can be added to the kit assay. When altering the sample volume adjust the distilled water volume added to the assay accordingly so that the total assay volume is not altered.

Q11. Can the test kit be used to measure biological fluids and what sample preparation method should be used?

The kit assay may work for biological fluids assuming that inositol is present above the limit of detection for the kit after any sample preparation (if required). Centrifugation of the samples and use of the supernatant directly in the kit assay (with appropriate dilution in distilled water) may be sufficient. However, if required a more stringent sample preparation method may be required and examples are provided at the following link:http://www.megazyme.com/docs/analytical-applications-downloads/biological_samples_111109.pdf?sfvrsn=2

The test kit has not been tested using biological fluids as samples because it is not marketed or registered as a medical device. This will therefore require your own validation.

Q12. Can the manual assay format be scaled down to a 96-well microplate format?

The majority of the Megazyme test kits are developed to work in cuvettes using the manual assay format, however the assay can be converted for use in a 96-well microplate format. To do this the assay volumes for the manual cuvette format are reduced by 10-fold. The calculation of results for the manual assay format uses a 1 cm path-length, however the path-length in the microplate is not 1 cm and therefore the MegaCalc spreadsheet or the calculation provided in the kit booklet for the manual format cannot be used for the micropalate format unless the microplate reader being used can.

There a 3 main methods for calculation of results using the microplate format:

  1. The easiest method is to use a microplate reader that has a path-length conversion capability (i.e. the microplater reader can detect the path-length of each well and convert the individual readings to a 1 cm path-length). This will allow values to be calculated using the MegaCalc calculation software which can be found where the product is located on the Megazyme website.
  2. Perform a standard curve of the analyte on each microplate that contains test samples and calculate the result of the test samples from the calibration curve (concentration of analyte versus absorbance).
  3. Perform a standard curve of the analyte in both the cuvette format (i.e. with a 1 cm path-length) and the 96-well microplate format and use these results to obtain a mean conversion factor between the cuvette values and the microplate values. Subsequent assays in the microplate format can then be converted from the calculated conversion factor.

Q13. Is it possible to add a larger volume then 2 μL of enzyme to the microplate assay? In some instances 2 μL can be difficult to pipette manually.

Yes, instead of adding 2 μL of enzyme suspension an alternative is to dilute the enzyme and add a larger volume to the microplate assay.

Dilute the assay buffer 10-fold with distilled water and use this as the diluent to dilute an aliquot of the enzyme suspension also by 10-fold. Instead of 2 μL, use 20 μL of the diluted enzyme in the microplate assay.

Q14. When using this kit for quantitative analysis what level of accuracy and repeatability can be expected?

The test kit is extremely accurate – at Megazyme the quality control criteria for accuracy and repeatability is to be within 2% of the expected value using pure analytes.

However, the level of accuracy is obviously analyst and sample dependent.

Q15. Must the minimum absorbance change for a sample always be at least 0.1?

No. The 0.1 change of absorbance is only a recommendation. The lowest acceptable change in absorbance can is dictated by the analyst and equipment (i.e. pipettes and spectrophotometer) and therefore can be can be determined by the user. With accurate pipetting, absorbance changes as low as 0.02 can be used accurately.
If a change in absorbance above 0.1 is required but cannot be achieved due to low concentrations of analyte in a sample, this can be overcome by using a larger sample volume in the assay to increase the absorbance change and thereby increase sensitivity of the assay. When doing this the increased volume of the sample should be subtracted from the distilled water volume that is added to the assay so that the total assay volume is unaltered. The increase sample volume should also be accounted for when calculating final results. 

 

Megazyme 溶解淀粉 操作视频

Megazyme 试剂盒样品前处理准备操作视频

Megazyme 柠檬酸检测试剂盒Citric Acid操作视频(K-CITR)

  •  件

Megazyme产品所有分类:
生物及食品酶法试剂盒(Assay Kits)
膳食纤维/淀粉(Dietary Fiber/Starch) 单/双糖(Mono/Disaccharides) 多糖(Polysaccharides) 醇类(Alcohols) 有机酸(Organic Acids) 亚硫酸盐/氮(Sulfite/Nitrogen) 活性酶(Enzyme Activity) 试剂混合物(Reagent Mixtures) 其它(Other)
酶(Enzymes)
活性酶(Carbohydrate Active enZYmes )
淀粉酶(Amylases )
阿拉伯树胶酸(Arabinanases)
阿拉伯呋喃(Arabinofuranosidases)
纤维二糖水解(Cellobiohydrolases)
纤维素酶(Cellulases)
酯酶(Esterases)
果糖酶&果糖苷酶(Fructanases & Fructosidases)
岩藻糖苷酶(Fucosidases)
半乳聚糖酶(Galactanases)
半乳糖苷酶(Galactosidases)
葡聚糖酶(Glucanases)
葡萄糖苷酶(Glucosidases)
葡糖醛酸糖苷(Glucuronidases)
已糖胺酶类(Hexosaminidiases)
裂解酶(Lyases)
甘露聚糖酶(Mannanases)
甘露糖苷酶(Mannosidases)
支链淀粉酶(Pullulanases)
唾液酸酶(Sialidases)
木聚糖酶(Xylanases)
糖苷酶(Xylosidases)
木葡聚糖酶(Xyloglucanases)
多聚半乳糖醛酸(内切)酶(Polygalacturonases)
其它酶(Other Activities)
分析酶(Analytical Enzymes)
脱氢酶(Dehydrogenases)
异构酶(Isomerases)
激酶(Kinases)
磷酸酶(Phosphatases)
蛋白酶(Proteases)
其他活性酶(Other Activities)
糖类活性酶(Glycobiology Enzymes)
酶底物( Chromogenic Substra